弊社の製品に関するご質問がございますか?弊社のエキスパートがお手伝いいたします。ご連絡ください 03-3864-0888
Zoom
T-Coupler Slimline M12 male/2xM12 female A-cod LED  7000-41135-0000000
Product may differ from image

T-Coupler Slimline M12 male/2xM12 female A-cod LED

5-pol. / 2x 4-pol.

Art.No.: 7000-41135-0000000
Alternative product:   
Weight: 0.029 kg
生産現国:  DE

製品説明

T-coupler (Slim Line)
Male straight – females straight
M12 – M12
5-pole
3× LED (PNP)
Distribution function (NO)
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Certificate
Certificate
Certificate
Certificate

Side 1
Tightening torque 0,6 Nm
Mounting method screwed, pluggable
Family construction form M12
Thread M12 x 1
Gender female
Coding A
No. of poles 4
Width across flats SW13
Degree of protection (EN IEC 60529) IP67
Side 2
Tightening torque 0,6 Nm
Mounting method screwed, pluggable
Family construction form M12
Thread M12 x 1
Gender female
Coding A
No. of poles 4
Width across flats SW13
Degree of protection (EN IEC 60529) IP67
Side 3
Mounting method screwed, pluggable
Family construction form M12
Coding A
No. of poles 5
Degree of protection (EN IEC 60529) IP67
Gender male
Tightening torque 0,6 Nm
Thread M12 x 1
Electrical data | Supply
Operating voltage DC 24 V
Operating voltage DC min. 18 V
Operating voltage DC max. 30 V
Operating voltage DC max. (UL-listed) 30 V
Current operating per contact max. 4 A
Diagnostics
Status indication LED green, white, yellow
Installation | Connection
Tightening torque 0,6 Nm
Mounting set M12 x 1
Width across flats SW 13
Device protection | Electrical
Additional condition protection degree inserted, screwed
Pollution Degree 3
Rated surge voltage 0,8 kV
Material group (IEC 60664-1) I
Mechanical data | Mounting data
Mounting method inserted, screwed, Shaking protection
Environmental characteristics | Climatic
Operating temperature min. -25 °C
Operating temperature max. 85 °C
Important installation notes
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Conformity
Product standard DIN EN 61076-2-101 (M12)

ECLASS-6.0 27143423
ECLASS-6.1 27279221
ECLASS-7.0 27440104
ECLASS-8.0 27440104
ECLASS-9.0 27440106
ECLASS-10.1 27440106
ECLASS-11.1 27440106
ECLASS-12.0 27440106
ETIM-5.0 EC002062
GTIN 4048879144858
HSコード 85366990
Packaging unit 1

 
Data Regarding Article:
  • 製品PDF
  • Certificate: ATEX 7000-18001_ax_2_k.pdf (K)
  • Construction files: P8 7000-41135-0000000_p8_2_10.zip (10)
  • Construction files: STP 7000-41135_stp_x_a.zip (A)
  • Information: Certificate of conformity Murrelektronik GmbH 16-12-23_(3) RoHS REACh exception 6c 7cI_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 12-12-23_(3) China RoHS 2 25EEP_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: EU declaration of conformity con_01-10.21_ce_z_c.pdf (C)