弊社の製品に関するご質問がございますか?弊社のエキスパートがお手伝いいたします。ご連絡ください 03-3864-0888
Zoom
M8 male 90° / M12 female 0° A-cod.  7000-88301-6300400
Product may differ from image

Last seen products

M8 male 90° / M12 female 0° A-cod.

PUR 3x0.25 bk UL/CSA+drag ch. 4m

Art.No.: 7000-88301-6300400
Weight: 0.122 kg
生産現国:  DE

製品説明



Male 90° – female straight
Male 90° – female straight
M8 – M12, 3-pole
M8 – M12, 3-pole
Further cable lengths on request.
Further cable lengths on request.
Plastic housings with good resistance against chemicals and oils.
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate

Cable length 4 m
Cable length 4 m
Side 1
Tightening torque 0,4 Nm
Tightening torque 0,4 Nm
Mounting method inserted, screwed
Mounting method inserted, screwed
Family construction form M8
Family construction form M8
Thread M8 x 1
Thread M8 x 1
suitable for corrugated tube (internal Ø) 6,5 mm
suitable for corrugated tube (internal Ø) 6,5 mm
Gender male
Gender male
Cable outlet angled
Cable outlet angled
Coding A
Coding A
Material contact Copper alloy
Material contact Copper alloy
No. of poles 3
No. of poles 3
Width across flats SW9
Width across flats SW9
Degree of protection (EN IEC 60529) IP65, IP66K, IP67
Degree of protection (EN IEC 60529) IP65, IP66K, IP67
Side 2
Tightening torque 0,6 Nm
Tightening torque 0,6 Nm
Mounting method inserted, screwed
Mounting method inserted, screwed
Family construction form M12
Family construction form M12
Thread M12 x 1
Thread M12 x 1
Gender female
Gender female
suitable for corrugated tube (internal Ø) 10 mm
suitable for corrugated tube (internal Ø) 10 mm
Cable outlet straight
Cable outlet straight
Coding A
Coding A
Material contact Copper alloy
Material contact Copper alloy
No. of poles 3
No. of poles 3
Width across flats SW13
Width across flats SW13
Degree of protection (EN IEC 60529) IP65, IP66K, IP67
Degree of protection (EN IEC 60529) IP65, IP66K, IP67
Electrical data | Supply
Operating voltage AC max. 50 V
Operating voltage AC max. 50 V
Operating voltage DC max. 60 V
Operating voltage DC max. 60 V
Operating voltage AC (UL-listed) 30 V
Operating voltage AC (UL-listed) 30 V
Operating voltage DC (UL-listed) 30 V
Operating voltage DC (UL-listed) 30 V
Current operating per contact max. 4 A
Current operating per contact max. 4 A
Diagnostics
Status indication LED no
Status indication LED no
Device protection | Electrical
Degree of protection (EN IEC 60529) IP65, IP67, IP68, IP66K
Degree of protection (EN IEC 60529) IP65, IP67, IP68, IP66K
Additional condition protection degree inserted, screwed
Additional condition protection degree inserted, screwed
Pollution Degree 3
Pollution Degree 3
Rated surge voltage 1,5 kV
Rated surge voltage 1,5 kV
Mechanical data | Material data
Coating locking Nickeled
Coating locking Nickeled
Material housing PUR
Material housing PUR
Locking material Zinc die-casting
Locking material Zinc die-casting
Mechanical data | Mounting data
Mounting method inserted, screwed, Shaking protection
Mounting method inserted, screwed, Shaking protection
Environmental characteristics | Climatic
Operating temperature min. -25 °C
Operating temperature min. -25 °C
Operating temperature max. 85 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality
Additional condition temperature range depending on cable quality
Important installation notes
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Conformity
Product standard DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8)
Product standard DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8)

Cable
wire arrangement brown, black, blue
wire arrangement brown, black, blue
General data | Cable
Cable identification 630
Cable identification 630
Cable Type 3
Cable Type 3
Jacket Color black
Jacket Color black
Type of Certificate cURus
Type of Certificate cURus
Structure | Cable
Amount stranding 1
Amount stranding 1
Stranding 3 wires twisted
Stranding 3 wires twisted
wire arrangement brown, black, blue
wire arrangement brown, black, blue
Mechanical data | Cable
Cable weigth 26,4 g/m
Cable weigth 26,4 g/m
Material jacket PUR
Material jacket PUR
Shore hardness jacket 90 ± 5 Shore A
Shore hardness jacket 90 ± 5 Shore A
Freedom from ingredients (jacket) lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Freedom from ingredients (jacket) lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Outer-diameter (jacket) 4,1 mm
Outer-diameter (jacket) 4,1 mm
Tolerance outer diameter (sheath) ± 5 %
Tolerance outer diameter (sheath) ± 5 %
Material wire insulation PP
Material wire insulation PP
Amount wires 3
Amount wires 3
Outer diameter insulation 1,25 mm
Outer diameter insulation 1,25 mm
Outer diameter tolerance core insulation ± 5 %
Outer diameter tolerance core insulation ± 5 %
Shore hardness wire insulation 70 ± 5 Shore D
Shore hardness wire insulation 70 ± 5 Shore D
Ingredient freeness wire insulation lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Ingredient freeness wire insulation lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Amount strands (wire) 32
Amount strands (wire) 32
Diameter of single wires 0,1 mm
Diameter of single wires 0,1 mm
Conductor crosssection (wire) 0,25 mm²
Conductor crosssection (wire) 0,25 mm²
Material conductor wire Stranded copper wire, bare
Material conductor wire Stranded copper wire, bare
Conductor type (wire) strand class 6
Conductor type (wire) strand class 6
Electrical data | Cable
Nominal voltage AC max. 300 V
Nominal voltage AC max. 300 V
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity (standard) to DIN VDE 0298-4
Current load capacity min. wire 4,5 A
Current load capacity min. wire 4,5 A
Electrical resistance line constant wire 79 Ω/km @ 20 °C
Electrical resistance line constant wire 79 Ω/km @ 20 °C
AC withstand voltage (wire - wire) 2,5 kV @ 60 s
AC withstand voltage (wire - wire) 2,5 kV @ 60 s
Power frequency withstand voltage (wire - jacket) 2,5 kV @ 60 s
Power frequency withstand voltage (wire - jacket) 2,5 kV @ 60 s
Temperature range | Cable
Min. operating temperature (static) -40 °C
Min. operating temperature (static) -40 °C
Max. operating temperature (fixed) 80 °C / 90 °C @ 10000 h Operation
Max. operating temperature (fixed) 80 °C / 90 °C @ 10000 h Operation
Operating temperature min. (dynamic) -25 °C
Operating temperature min. (dynamic) -25 °C
Operating temperature max. (dynamic) 80 °C / 90 °C @ 10000 h Operation
Operating temperature max. (dynamic) 80 °C / 90 °C @ 10000 h Operation
Resistances | Cable
UV resistance DIN EN ISO 4892-2 A
UV resistance DIN EN ISO 4892-2 A
Flame resistance UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
Flame resistance UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
chemical resistance Good, application-related testing
chemical resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Oil resistance Good, application-related testing | DIN EN 60811-404
Oil resistance Good, application-related testing | DIN EN 60811-404
Installation | Cable
Bending radius (fixed) 5 x Outer diameter
Bending radius (fixed) 5 x Outer diameter
Bending radius (dynamic) 10 x Outer diameter
Bending radius (dynamic) 10 x Outer diameter
No. of bending cycles (C-track) 10 Mio. @ 25 °C
No. of bending cycles (C-track) 10 Mio. @ 25 °C
Traversing distance (C-track) 10 m @ 25 °C | horizontal
Traversing distance (C-track) 10 m @ 25 °C | horizontal
Travel speed (C-track) 3 m/s @ 25 °C
Travel speed (C-track) 3 m/s @ 25 °C
No. of torsion cycles 2 Mio.
No. of torsion cycles 2 Mio.
Torsion stress ± 180 °/m
Torsion stress ± 180 °/m
Torsion speed 35 cycles/min
Torsion speed 35 cycles/min

ECLASS-6.0 27061801
ECLASS-6.0 27061801
ECLASS-6.1 27279218
ECLASS-6.1 27279218
ECLASS-7.0 27279218
ECLASS-7.0 27279218
ECLASS-8.0 27279218
ECLASS-8.0 27279218
ECLASS-9.0 27060311
ECLASS-9.0 27060311
ECLASS-10.1 27060311
ECLASS-10.1 27060311
ECLASS-11.1 27060311
ECLASS-11.1 27060311
ECLASS-12.0 27060311
ECLASS-12.0 27060311
GTIN 4065909055410
HSコード 85444290
Packaging unit 1

 
Data Regarding Article:
  • 製品PDF
  • Approval: CSA CA 080128-0-000_csa_z_c.pdf (C)
  • Approval: CSA US 080128-0-000_csau_z_c.pdf (C)
  • Approval: UL Listed CA E325311-CYJV_ulc_z_b.pdf (B)
  • Approval: UL Listed US E325311-CYJV_ul_z_d.pdf (D)
  • Certificate: ATEX 7000-18001_ax_2_k.pdf (K)
  • Construction files: STP 7000-88301_stp_x_a.zip (A)
  • Document: ATEX 7000-18001_atx_2_l.pdf (L)
  • Information: Certificate of conformity Murrelektronik GmbH 17-12-23_(1) RoHS REACh exception 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 13-12-23_(5) China RoHS 2 50EEP_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: EU declaration of conformity 7000-40561_18-08.19_ce_z_c.pdf (C)