Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Drive Cliq IP20/ M12 fem. recept. A-cod. shielded

PVC AWG24+22 shielded gn UL/CSA+drag ch. 1.5m

Art.No.: 7000-SS075-8810150
Weight: 0.152 kg
Country of origin:  DE

Description


Ethernet CAT5
Flange female straight – male straight
DRIVE-CLiQ IP20
M12, 8-pole
partly used
shielded
without cable sleeves
Rear mounting
Further cable lengths on request.
The resistance to aggressive media should be individually tested for your application. Further details on request.
Bus technologies
Bus technologies

Cable length 1,5 m
Side 1
Tightening torque 0,6 Nm
Family construction form M12
Thread M12 x 1
Coding A
Degree of protection (EN IEC 60529) IP67
Side 2
Family construction form DRIVE-CLiQ
Degree of protection (EN IEC 60529) IP20
Electrical data | Supply
Operating voltage AC max. 30 V
Operating voltage DC max. 30 V
Current operating per contact max. 1,76 A
Industrial communication
Transfer parameters CAT5, Class D (ISO/IEC 11801:2002), (EN 50173-1)
Data transmission rate max. 100 MBit/s
Industrial communication | Ethernet functionality
duplex Full duplex
Installation | Connection
Family construction form M12
Width across flats SW19
Device protection | Electrical
Protection NEMA 3, 4, 6P
Pollution Degree 3
Rated surge voltage 0,5 kV
Material group (IEC 60664-1) II
Mechanical data | Material data
Coating locking nickel plated
Material housing PUR
Locking material Brass
Mechanical data | Mounting data
Mounting method inserted, screwed, Shaking protection
Environmental characteristics | Climatic
Operating temperature min. -25 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality
Important installation notes
Note on strain relief Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Note on bending radius Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Approvals
UL 50E yes

Cable
wire arrangement (green, yellow), (pink, blue), (red, black)
General data | Cable
Cable identification 881
Function cable Hybrid, Data, Power
Jacket Color green
Type of Certificate cURus
Structure | Cable
Amount stranding 3
Stranding 2 wires with Filler twisted
Stranding (type 2) 3 Stranded joints with Filler twisted
Cable shielding (type) copper braid, tinned
Cable shielding (coverage) 85 %
Filler yes
wire arrangement (green, yellow), (pink, blue), (red, black)
Mechanical data | Cable
Material jacket PVC
Freedom from ingredients (jacket) lead-free, CFC-free, silicone-free
Outer-diameter (jacket) 6,95 mm
Tolerance outer diameter (sheath) ± 5 %
Material wire insulation PE
Amount wires 4
Outer diameter insulation 1,03 mm
Outer diameter tolerance core insulation ± 5 %
Ingredient freeness wire insulation lead-free, CFC-free, halogen-free, silicone-free
Amount strands (wire) 7
Diameter of single wires 24 AWG
Conductor crosssection (wire) 24 AWG
Material conductor wire Stranded copper wire, bare
Electrical function wire Data
Material wire insulation (Power) PE
Outer diameter wire insulation (Power) 1,03 mm
Tolerance outer diameter wire insulation (Power) ±5 %
Ingredient freeness wire insulation (Power) lead-free, CFC-free, halogen-free
Amount wires (Power) 2
Amount strands wire (Power) 7
Diameter of single wires (Power) 22 AWG
Wire conductor cross section (Power) 22 AWG
Material conductor wire (Power) copper stranded wire, tinned
Electrical data | Cable
Nominal voltage AC max. 30 V
Electrical function wire Data
Characteristic impedance 100 Ω ± 15 % @ 1 MHz
Electrical resistance line constant wire 90 Ω/km @ 20 °C
Electrical resistance coating wire (Power) 55 Ω/km @20 °C
AC withstand voltage (wire - wire) 0,5 kV @ 60 s
Electric capacitance 50000 pF/km
Power frequency withstand voltage (wire - jacket) 0,5 kV @ 60 s
AC withstand voltage (wire - shield) 0,5 kV @ 60 s
Isolation resistance 1000 MΩ × km
Temperature range | Cable
Min. operating temperature (static) -20 °C
Max. operating temperature (fixed) 80 °C
Operating temperature min. (dynamic) 0 °C
Operating temperature max. (dynamic) 60 °C
Resistances | Cable
Flame resistance UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
chemical resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Oil resistance Good, application-related testing | DIN EN 60811-404
Installation | Cable
No. of bending cycles (C-track) 0,1 Mio.
Traversing distance (C-track) 10 m @ 25 °C | horizontal
Travel speed (C-track) 0,5 m/s @ 25 °C

ECLASS-6.0 27061801
ECLASS-6.1 27279220
ECLASS-7.0 27440103
ECLASS-8.0 27440103
ECLASS-9.0 27440103
ECLASS-10.1 27440103
ECLASS-11.1 27440103
ECLASS-12.0 27440103
ETIM-5.0 EC001855
customs tariff number 85444290
GTIN 4048879618328
Packaging unit 1

 
Data Regarding Article:
  • Product-PDF
  • Information: Certificate of conformity Murrelektronik GmbH 17-12-23_(1) RoHS REACh exception 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 13-12-23_(5) China RoHS 2 50EEP_DoC_z_a.pdf (01)
  • Information: Certificate of conformity Murrelektronik GmbH 06-05-24_(8) REACH SVHC CAS No 80-09-1_DoC_z_a.pdf (01)