General data | Cable
Cable identification |
801 |
Jacket Color |
violet |
Structure | Cable
Amount stranding |
2 |
Stranding |
2 wires twisted |
Amount stranding (type 2) |
1 |
Stranding (type 2) |
2 Stranded joints with 2 Filler twisted |
Stranding factor min. (type 2) |
50 mm |
Stranding factor max. (type 2) |
50 mm |
Cable shielding (type) |
copper braid, tinned |
Cable shielding (coverage) |
85 % |
Banding |
Fleece |
Filler |
yes |
wire arrangement |
(white, brown), (green, yellow) |
Mechanical data | Cable
Cable weigth |
64,88 g/m |
Material jacket |
PUR |
Shore hardness jacket |
85 Shore A |
Freedom from ingredients (jacket) |
lead-free, CFC-free, halogen-free |
Outer-diameter (jacket) |
6,8 mm |
Tolerance outer diameter (sheath) |
± 5 % |
Material wire insulation |
PP |
Amount wires |
4 |
Outer diameter insulation |
1,36 mm |
Outer diameter tolerance core insulation |
± 5 % |
Shore hardness wire insulation |
92 Shore A |
Ingredient freeness wire insulation |
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free |
Amount strands (wire) |
32 |
Diameter of single wires |
0,1 mm |
Conductor crosssection (wire) |
0,25 mm² |
Material conductor wire |
Stranded copper wire, bare |
Conductor type (wire) |
strand class 6 |
Electrical data | Cable
Nominal voltage AC max. |
350 V |
Current load capacity (standard) |
to DIN VDE 0298-4 |
Current load capacity min. wire |
3,4 A |
Characteristic impedance |
120 Ω ± 15 % @ 1 MHz |
Electrical resistance line constant wire |
87,6 Ω/km @ 20 °C |
AC withstand voltage (wire - wire) |
1,5 kV @ 60 s |
Electrical capacity line constant (wire - wire) |
47000 pF/km |
Power frequency withstand voltage (wire - jacket) |
1,5 kV @ 60 s |
AC withstand voltage (wire - shield) |
1 kV @ 60 s |
Temperature range | Cable
Min. operating temperature (static) |
-40 °C |
Max. operating temperature (fixed) |
80 °C |
Operating temperature min. (dynamic) |
-20 °C |
Operating temperature max. (dynamic) |
80 °C |
Resistances | Cable
Flame resistance |
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090 |
chemical resistance |
Good, application-related testing |
Gasoline resistance |
Good, application-related testing |
Oil resistance |
Good, application-related testing | DIN EN 60811-404 |
Installation | Cable
Bending radius (fixed) |
7,5 x Outer diameter |
Bending radius (dynamic) |
12 x Outer diameter |