Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Thread:
Side 2
Tightening torque:
Thread:
Electrical data | Supply
Current operating per contact max.:
Current phase - neutral:
Current phase - phase:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Rated surge voltage:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Cable Type:
Printing color of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Filler:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Traversing distance (C-track):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
Packaging unit:
customs tariff number:
Approvals
Certificates
Certificate
Move
Mini (7/8) 5 pole, Male (Ext.) 0°/Female 0° Mini (7/8) 5 pole, Male (Ext.) 0°/Female 0°
PUR 5x1.5 (5x16AWG) bk UL/CSA
Weight: 0.153 kg
Art.No.: 7700-A5A01-UMD0100

Move
7/8'' male 0° / 7/8'' female 0° 7/8'' male 0° / 7/8'' female 0°
PUR 5x1.5 gy UL/CSA+drag ch. 1m
Weight: 0.23 kg
Art.No.: 7000-50021-9610100

-
1 m
-
1,5 Nm
-
7/8"
-
1,5 Nm
-
7/8"
-
12 A
-
230 V
-
400 V
-
IP67
-
inserted, screwed
-
3 kV
-
inserted, screwed, Shaking protection
-
-25 °C
-
85 °C
-
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
961
-
3
-
black (white isolation), white (isolation blue), white (isolation brown), white (isolation black)
-
gray
-
cURus
-
1
-
5 wires around Filler twisted
-
yes
-
green-yellow, blue 2, black 1, white 4, brown 3
-
129,8 g/m
-
PUR
-
90 ± 5 Shore A
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
8 mm
-
± 5 %
-
PP
-
5
-
2,3 mm
-
± 5 %
-
60 ± 5 Shore D
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
black (white isolation), white (isolation blue), white (isolation brown), white (isolation black)
-
84
-
0,15 mm
-
1,5 mm²
-
Stranded copper wire, bare
-
strand class 6
-
5 m @ 25 °C
-
1000 V
-
to DIN VDE 0298-4
-
13,5 A
-
13,3 Ω/km @ 20 °C
-
10 kV @ 60 s
-
10 kV @ 60 s
-
-50 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-25 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
-
Good, application-related testing
-
Good, application-related testing
-
DIN EN 60811-404 | Good, application-related testing
-
7,5 x Outer diameter
-
10 x Outer diameter
-
5 Mio. @ 25 °C
-
2 Mio.
-
± 180 °/m
-
35 cycles/min
-
27279218
-
27279218
-
27279218
-
27279218
-
27060327
-
27060311
-
27060311
-
27060327
-
EC001855
4048879640565
4048879138765
1
1
85444290
85444290
-