Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Product Comparison for 2 products

 Forward
Article
Technical Data
Side 1
Family construction form:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC max.:
Current operating per contact max.:
Current operating per contact max. (URc.):
Installation
Connection cross section max.:
Installation | Connection
Tightening torque:
Mounting set:
Width across flats:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Overvoltage category (EN 60664-1):
Overvoltage category (EN 60950-1):
Mechanical data | Material data
Material housing:
Locking material:
Mechanical data | Mounting data
Mounting method:
Clamping range min.:
Clamping range max.:
Height:
Width:
Depth:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Important installation notes
Note on strain relief:
Note on bending radius:
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
customs tariff number:
GTIN:
Packaging unit:
Approvals
Certificates
Certificate
Move
M12 female 0° A-cod. screw terminal V4A M12 female 0° A-cod. screw terminal V4A
5-pol., max. 0,75mm², 6 - 8mm
Weight: 0.03 kg
Art.No.: 7004-12961-0000000

Move
M12 female 90° A-cod. screw terminal V4A M12 female 90° A-cod. screw terminal V4A
5-pol., max. 0,75mm², 6 - 8mm
Weight: 0.03 kg
Art.No.: 7004-13041-0000000

M12
M12
IP67
IP67
60 V
60 V
4 A
4 A
3 A
3 A
0,75 mm²
0,75 mm²
0,6 Nm
0,6 Nm
M12 x 1
M12 x 1
SW18
SW18
inserted, screwed
inserted, screwed
3
3
0,8 kV
0,8 kV
III
III
II
II
PA
PA
Stainless steel 1.4404 (V4A)
Stainless steel 1.4404 (V4A)
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
6 mm
6 mm
8 mm
8 mm
54 mm
-
20 mm
-
20 mm
-
-40 °C
-40 °C
85 °C
85 °C
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
27279221
27279221
27440104
27440104
27440104
27440104
27440102
27440102
27440102
27440102
27440102
27440102
27440116
27440116
EC002635
EC002635
85366990
85366990
4048879110938
4048879110921
1
1