Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Family construction form:
Thread:
Cable outlet:
Coding:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC max.:
Current operating per contact max.:
Industrial communication
Transfer parameters:
Data transmission rate max.:
Industrial communication | Ethernet functionality
duplex:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data
Contour for corrugated hose:
Mechanical data | Material data
Coating locking:
Locking material:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
Cable
wire arrangement:
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Cable shielding (type):
Cable shielding (coverage):
Banding:
Filler:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Characteristic impedance:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Electrical capacity line constant (wire - wire):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Isolation resistance:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
Packaging unit:
customs tariff number:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 male 0° / M12 male 0° D-cod. shielded M12 male 0° / M12 male 0° D-cod. shielded
PUR 1x4xAWG22 shielded gn UL/CSA 15m
Weight: 0.975 kg
Art.No.: 7000-44511-7941500

Move
M12 male 0° / M12 male 0° D-cod. shielded M12 male 0° / M12 male 0° D-cod. shielded
PUR 1x4xAWG22 shielded gn UL/CSA+drag ch. 15m
Weight: 1.069 kg
Art.No.: 7000-44511-7961500

15 m
15 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
straight
straight
D
D
PUR
PUR
4
4
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
straight
straight
D
D
PUR
PUR
4
4
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
60 V
60 V
1,5 A
1,5 A
CAT5e, Class D (ISO/IEC 11801:2002), (EN 50173-1)
CAT5e, Class D (ISO/IEC 11801:2002), (EN 50173-1)
100 MBit/s
100 MBit/s
Full duplex
Full duplex
IP65, IP67, IP66K
IP65, IP67, IP66K
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
without
without
Nickeled
Nickeled
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
-
white, yellow, blue, orange
794
796
green
green
cURus
cURus
1
1
4 wires around Filler twisted
4 wires around Core filler twisted
copper braid, tinned
copper braid, tinned
85 %
85 %
Fleece, Foil
Fleece, Foil
yes
yes
white, yellow, blue, orange
white, yellow, blue, orange
75,87 g/m
69,3 g/m
PUR
PUR
89 Shore A
89 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6,7 mm
6,7 mm
± 5 %
± 5 %
FRNC
FRNC
white
natur
PE
PE
4
4
1,55 mm
1,4 mm
± 5 %
± 5 %
65 Shore D
65 Shore D
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
7
7
22 AWG
22 AWG
22 AWG
22 AWG
Stranded copper wire, bare
Stranded copper wire, bare
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,8 A
4,8 A
100 Ω ± 15 %
100 Ω ± 15 % @ 100 MHz
55 Ω/km @ 20 °C
55 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
52000 pF/km
50000 pF/km
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-
5000 MΩ × km
-40 °C
-40 °C
80 °C
80 °C
-30 °C
-30 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
6 x Outer diameter
5 x Outer diameter
12 x Outer diameter
12 x Outer diameter
-
3 Mio. @ 25 °C
-
5 m @ 25 °C
-
3,3 m/s @ 25 °C
-
1 Mio. 25 °C
-
± 180 °/m
27061801
27061801
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
EC002599
EC002599
4048879403924
4048879141260
1
1
85444290