Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
Coding:
Material:
No. of poles:
Width across flats:
Side 2
Tightening torque:
Mounting method:
Family construction form:
Thread:
Coding:
Material:
No. of poles:
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Diagnostics
Status indication LED:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data
Contour for corrugated hose:
Mechanical data | Material data
Coating locking:
Locking material:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
General data | Cable
STOOW style jacket:
Cable identification:
Cable Type:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Stranding factor max. (type 5):
Amount stranding:
Stranding:
Stranding factor min.:
Stranding factor max.:
Amount stranding (type 2):
Stranding (type 2):
Stranding factor min. (type 2):
Stranding factor max. (type 2):
Amount stranding (type 3):
Stranding (type 3):
Stranding factor min. (type 3):
Stranding factor max. (type 3):
Cable shielding (type):
Cable shielding (coverage):
Pair shielding (type):
Banding:
Filler:
Drain wire (type):
Drain wire (cross-section):
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Cable length max.:
Cable weigth:
Material jacket:
Shore hardness jacket:
Travel speed (C-track):
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Resistances wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Drain wire (cross-section):
Material conductor wire:
Conductor type (wire):
Electrical function wire:
Material wire insulation (Data):
Outer diameter wire insulation (Data):
Tolerance outer diameter wire insulation (data):
Shore hardness wire insulation (Data) :
Material properties wire insulation (Data):
Ingredient freeness wire insulation (Data):
Resistances wire insulation (Data):
Printing color wire insulation (data):
Printing spacing wire insulation (Data):
Amount wires (Data):
Amount strands wire (Data):
Diameter of single wires (Data):
Conductor crosssection wire (Data):
Material conductor wire (Data):
Wire conductor type (Data):
Electrical function wire (data):
Material wire insulation (Power):
Outer diameter wire insulation (Power):
Tolerance outer diameter wire insulation (Power):
Shore hardness wire insulation (Power):
Material properties wire insulation (Power):
Ingredient freeness wire insulation (Power):
Resistances wire insulation (Power):
Printing colour wire insulation (Power):
Printing spacing wire insulation (Power):
Amount strands wire (Power):
Diameter of single wires (Power):
Wire conductor cross section (Power):
Material conductor wire (Power):
Conductor type wire (Power):
Electrical function wire (Power):
Electrical data | Cable
Loop resistance:
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Electrical function wire:
Electrical function wire (data):
Characteristic impedance:
Electrical resistance line constant wire:
Electrical resistance coating wire (Power):
Electrical resistance coating wire (Data):
AC withstand voltage (wire - wire):
Electric inductivity line constant:
Electric capacitance:
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Transmission frequency range:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Storage temperature min.:
Storage temperature max.:
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (installation):
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
customs tariff number:
Packaging unit:
Approvals
Certificates
Certificate
Certificate
Move
M12 male 0° / M12 female 0° B-cod. shielded M12 male 0° / M12 female 0° B-cod. shielded
PUR AWG24+22 shielded vt UL/CSA+drag ch. 7.5m
Weight: 0.509 kg
Art.No.: 7000-44032-8030750

Move
M12 male 0° / M12 female 0° B-cod. shielded M12 male 0° / M12 female 0° B-cod. shielded
PUR AWG24+22 shielded vt UL/CSA+drag ch. 10m
Weight: 0.669 kg
Art.No.: 7000-44032-8031000

7,5 m
10 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
B
B
PUR
PUR
4
4
SW13
SW13
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
B
B
PUR
PUR
4
4
60 V
60 V
60 V
60 V
30 V
30 V
30 V
30 V
4 A
4 A
no
no
IP67
IP67
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
without
without
Nickeled
Nickeled
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
-
-
803
803
-
-
-
-
-
-
violet
violet
cURus
cURus
-
-
1
1
2 wires twisted
2 wires twisted
-
-
-
-
1
1
2 Stranded joints twisted
2 Stranded joints twisted
-
-
-
-
-
-
-
-
-
-
-
-
copper braid, tinned
copper braid, tinned
65 %
65 %
-
-
Foil
Foil
-
-
-
-
22 AWG
22 AWG
(white, blue), (black, red)
(white, blue), (black, red)
5 m
5 m
-
-
63,12 g/m
63,12 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
-
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6,9 mm
6,9 mm
± 5 %
± 5 %
-
-
-
-
PE
PE
2
2
2,1 mm
2,1 mm
± 5 %
± 5 %
64 ± 5 Shore D
64 ± 5 Shore D
-
-
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
19
19
24 AWG
24 AWG
24 AWG
24 AWG
22 AWG
22 AWG
copper stranded wire, tinned
copper stranded wire, tinned
-
-
Data
Data
PE
PE
1,5 mm
1,5 mm
± 53 %
± 53 %
-
-
-
-
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
2
2
19
19
22 AWG
22 AWG
22 AWG
22 AWG
copper stranded wire, tinned
copper stranded wire, tinned
-
-
Power
Power
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
300 V
300 V
-
-
-
-
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
6 A
6 A
Data
Data
Power
Power
120 Ω ± 10 % @ 1 MHz
120 Ω ± 10 % @ 1 MHz
78 Ω/km
78 Ω/km
-
-
54 Ω/km
54 Ω/km
2 kV @ 60 s
2 kV @ 60 s
-
-
40000 pF/km
40000 pF/km
-
-
-
-
-
-
2 kV @ 60 s
2 kV @ 60 s
-
-
-40 °C
-40 °C
80 °C
80 °C
-30 °C
-30 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
x Outer diameter
x Outer diameter
6 x Outer diameter
6 x Outer diameter
10 x Outer diameter
10 x Outer diameter
1 Mio.
1 Mio.
2 Mio.
2 Mio.
± 30 °/m
± 30 °/m
35 cycles/min
35 cycles/min
27061801
27061801
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
27060307
EC001855
EC001855
4048879296304
4048879141741
85444290
85444290
1
1