Product questions? We’re happy to help! Find your local Murrelektronik Representative.

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Family construction form:
Thread:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Family construction form:
Thread:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Current consumption max.:
Device protection | Electrical
Additional condition protection degree:
Rated surge voltage:
Mechanical data | Material data
Color housing:
Material housing:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Filler:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
GTIN:
Packaging unit:
customs tariff number:
Approvals
Certificates
Certificate
Move
M12 male 90° A-cod. / MSUD valve plug A-18mm M12 male 90° A-cod. / MSUD valve plug A-18mm
PVC 5x0.34 gy UL/CSA 1m
Weight: 0.103 kg
Art.No.: 7000-40951-2150100

Move
M12 male 90° A-cod. / MSUD valve plug A-18mm M12 male 90° A-cod. / MSUD valve plug A-18mm
PVC 5x0.34 ye UL/CSA 1m
Weight: 0.103 kg
Art.No.: 7000-40951-0150100

1 m
1 m
0,4 Nm
0,4 Nm
MSUD
MSUD
M3
M3
IP66K, IP67
IP66K, IP67
0,6 Nm
0,6 Nm
M12
M12
M12 x 1
M12 x 1
IP66K, IP67
IP66K, IP67
24 V
24 V
18 V
18 V
30 V
30 V
4 A
4 A
12 mA
12 mA
inserted, screwed
inserted, screwed
0,8 kV
0,8 kV
black
black
Plastic
Plastic
inserted, screwed
inserted, screwed
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
215
015
1
1
gray
yellow
cURus
cURus
1
1
5 wires around Core filler twisted
5 wires around Core filler twisted
yes
yes
brown, black, blue, white, green-yellow
brown, black, blue, white, green-yellow
48,4 g/m
48,4 g/m
PVC
PVC
85 ± 5 Shore A
85 ± 5 Shore A
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
5,2 mm
5,2 mm
± 5 %
± 5 %
PVC
PVC
5
5
1,25 mm
1,25 mm
± 5 %
± 5 %
45 ± 5 Shore D
45 ± 5 Shore D
good machinability
good machinability
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
19
19
0,15 mm
0,15 mm
0,34 mm²
0,34 mm²
Stranded copper wire, bare
Stranded copper wire, bare
Strand class 5
Strand class 5
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
57 Ω/km @ 20 °C
57 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-30 °C
-30 °C
80 °C
80 °C
-5 °C
-5 °C
80 °C
80 °C
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879149525
4048879149549
1
1
85444290
85444290