弊社の製品に関するご質問がございますか?弊社のエキスパートがお手伝いいたします。ご連絡ください 03-3864-0888

Product Comparison for 2 products

 フォワード
Article
技術情報
Cable length:
Side 1
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Gender:
Cable outlet:
Coding:
Material contact:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
Gender:
suitable for corrugated tube (internal Ø):
Cable outlet:
Coding:
Material contact:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Operating voltage DC max. (UL-listed):
Current operating per contact max.:
Current consumption max.:
Electrical data | Input
Input voltage OFF DC min.:
Input voltage OFF DC max.:
Input voltage DC min.:
Input voltage DC max.:
Current input DC:
Electrical data | Output
Overload resistant:
Short-circuit protected:
Switch-off delay resistive load max.:
On-delay resistive load max.:
Quiescent current OFF max.:
Switching frequency inductive max.:
Switching frequency ohmic max.:
Voltage switching DC min.:
Switching voltage DC max.:
Switching current min.:
Switching current max.:
Voltage drop DC max.:
Diagnostics
Status indication LED:
Status indication LED:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Rated insulation voltage:
Pulse switching:
Device protection | Media
Flame resistance:
Mechanical data | Material data
Coating locking:
Coating of fitting:
Color housing:
Material gasket:
Material housing:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Mounting method:
Suitable for mounting type:
Height:
Width:
Depth:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature min.:
Operating temperature max.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
ケーブルデータ
Cable
wire arrangement:
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
接続仕様
Connection type 1
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
Connection type 2
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
Connection type 3
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
Connection type 4
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
取引条件
Packaging unit:
GTIN:
HSコード:
認証
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 male 0° / M8 female 90° A-cod. LED M12 male 0° / M8 female 90° A-cod. LED
PUR 3x0.25 bk UL/CSA+drag ch. 0.3m
Weight: 0.023 kg
Art.No.: 7000-40641-6300030

Move
MIRO TR 24VDC 24VDC 10A SK OPTO-COUPLER MODULE MIRO TR 24VDC 24VDC 10A SK OPTO-COUPLER MODULE
IN: 53 VDC - OUT: 48 VDC / 10 A
Weight: 0.04 kg
Art.No.: 52521

0,3 m
-
0,6 Nm
-
inserted, screwed
-
gold plated
-
M12
-
M12 x 1
-
10 mm
-
male
-
straight
-
A
-
Copper alloy
-
PUR
-
3
-
SW13
-
IP66K, IP67
-
0,4 Nm
-
inserted, screwed
-
gold plated
-
M8
-
M8 x 1
-
female
-
6,5 mm
-
angled
-
A
-
Copper alloy
-
PUR
-
3
-
SW9
-
IP66K, IP67
-
24 V
-
18 V
-
30 V
-
30 V
-
4 A
-
5 mA
-
-
0 V
-
5 V
-
10 V
-
53 V
-
10 mA
-
yes
-
yes
-
5000 µs
-
2000 µs
-
0,025 mA
-
0,1 Hz
-
1 Hz
-
5 V
-
48 V
-
1 mA
-
10 A
-
0,12 V
green, yellow
-
-
yellow
inserted, screwed
-
3
-
0,8 kV
-
I
-
-
2750 V
-
yes
-
flame retardant
Nickeled
-
nickel plated
-
-
black
FKM
-
-
Plastic
Zinc die-casting
-
Zinc die-casting
-
inserted, screwed, Shaking protection
-
-
geschnappt
-
mounting rail, (EN 60715)
-
78 mm
-
6,2 mm
-
70 mm
-25 °C
-
-
-20 °C
85 °C
-
-
60 °C
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
DIN EN 61076-2-101 (M12), DIN EN 61076-2-104 (M8)
-
brown, black, blue
-
630
-
3
-
black
-
cURus
-
1
-
3 wires twisted
-
brown, black, blue
-
26,4 g/m
-
PUR
-
90 ± 5 Shore A
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
4,1 mm
-
± 5 %
-
PP
-
3
-
1,25 mm
-
± 5 %
-
70 ± 5 Shore D
-
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
32
-
0,1 mm
-
0,25 mm²
-
Stranded copper wire, bare
-
strand class 6
-
300 V
-
to DIN VDE 0298-4
-
4,5 A
-
79 Ω/km @ 20 °C
-
2,5 kV @ 60 s
-
2,5 kV @ 60 s
-
-40 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-25 °C
-
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
-
UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
-
Good, application-related testing
-
Good, application-related testing
-
Good, application-related testing | DIN EN 60811-404
-
5 x Outer diameter
-
10 x Outer diameter
-
10 Mio. @ 25 °C
-
10 m @ 25 °C | horizontal
-
3 m/s @ 25 °C
-
2 Mio.
-
± 180 °/m
-
35 cycles/min
-
-
Screw terminals SK
-
terminal
-
female
-
green
-
1
-
13 +
-
Screw terminals SK
-
terminal
-
female
-
green
-
1
-
14
-
Screw terminals SK
-
terminal
-
female
-
green
-
1
-
A 1
-
Screw terminals SK
-
terminal
-
female
-
green
-
1
-
A 2
27279218
27371604
-
27371604
27279218
27371604
27279218
27371604
27060311
27371604
27060311
27371604
27060311
27371604
27060311
27371604
EC001855
EC001504
1
1
4048879159340
4048879026796
85444290
85414900
-
-
-