弊社の製品に関するご質問がございますか?弊社のエキスパートがお手伝いいたします。ご連絡ください 03-3864-0888

Product Comparison for 2 products

 フォワード
Article
技術情報
Cable length:
Side 1
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material contact:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material contact:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Side 3
Mounting method:
Family construction form:
Coding:
No. of poles:
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Electrical data | Input
Input voltage AC:
Input voltage AC min.:
Input voltage AC max.:
Input voltage DC:
Input voltage DC min.:
Input voltage DC max.:
Input current:
Electrical data | Output
Utilization category DC-13 (EN IEC 60947-5-1):
Additional condition switching frequency:
Switching frequency max.:
Power rating AC max.:
Power rating DC max.:
Switching voltage AC max.:
Switching voltage DC max.:
Switching current DC:
Switching current max.:
Switching capacity AC-12 (EN IEC 60947-5-1):
Switching capacity AC-15 (EN IEC 60947-5-1):
Diagnostics
Status indication LED:
Status indication LED:
Device protection
Condition lifetime:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Rated surge voltage:
Electrical lifetime:
Device protection | Mechanical
Mechanical endurance:
Mechanical data
Drop-out time max.:
Response time max.:
Bounce time max.:
Mechanical data | Material data
Coating locking:
Material gasket:
Material contact:
Locking material:
Mechanical data | Mounting data
Mounting method:
Mounting method:
Suitable for mounting type:
Height:
Width:
Depth:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature min.:
Operating temperature max.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
ケーブルデータ
Cable
wire arrangement:
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
接続仕様
Connection types
Connection type 1:
Connection type 2:
Connection type 3:
Connection type 4:
Connection type 1
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
PIN 4:
Connection type 2
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
PIN 4:
Connection type 3
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
Connection type 4
Connection:
Family construction form:
Gender:
Color contact carrier:
No. of poles:
PIN 1:
PIN 2:
PIN 3:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
取引条件
GTIN:
Packaging unit:
HSコード:
認証
Certificates
Certificate
Certificate
Certificate
Certificate
Move
Y-Distributor M12 male / M8 female 0° A-cod. Y-Distributor M12 male / M8 female 0° A-cod.
PVC 3x0.25 gy UL/CSA 1.5m
Weight: 0.105 kg
Art.No.: 7000-40821-2100150

Move
RM 14/24 VAC/DC KL.BZ.N.EN OUTPUT RELAY RM 14/24 VAC/DC KL.BZ.N.EN OUTPUT RELAY
IN: 24 VAC/DC - OUT: 250 VAC/DC / 2 A
Weight: 0.096 kg
Art.No.: 51410

1,5 m
-
0,6 Nm
-
inserted, screwed
-
gold plated
-
M12
-
M12 x 1
-
10 mm
-
A
-
Copper alloy
-
PUR
-
4
-
SW13
-
IP65, IP66K, IP67
-
0,4 Nm
-
inserted, screwed
-
gold plated
-
M8
-
M8 x 1
-
6,5 mm
-
A
-
Copper alloy
-
PUR
-
3
-
SW9
-
IP65, IP66K, IP67
-
inserted, screwed
-
M8
-
A
-
3
-
50 V
-
60 V
-
30 V
-
30 V
-
4 A
-
-
24 V
-
20,4 V
-
26,4 V
-
24 V
-
20,4 V
-
26,4 V
-
20 mA
-
0,8 A @ 24 V, 0,01 A @ 230 V
-
with load
-
0,1 Hz
-
125 VA
-
60 W
-
250 V
-
250 V
-
0,1 mA
-
2 A
-
2 A (24 V AC); 0.5 A (230 V AC)
-
1 A (24 V AC); 0.1 A (230 V AC)
no
-
-
red
-
load-dependent
inserted, screwed
-
3
-
1,5 kV
-
I
-
-
1,5 kV
-
50000000 Cycles
-
50000000 Cycles
-
20 ms
-
10 ms
-
2 ms
Nickeled
-
FKM
-
-
Ag Au
Zinc die-casting
-
inserted, screwed, Shaking protection
-
-
geschnappt
-
Mounting rail TH35, G32, (EN 60715)
-
75 mm
-
22,5 mm
-
102 mm
-25 °C
-
-
-20 °C
85 °C
-
-
50 °C
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
-
DIN EN 61076-2-101 (M12), DIN EN 61076-2-114 (M8)
-
brown, black, blue
-
210
-
1
-
gray
-
cURus
-
1
-
3 wires twisted
-
brown, black, blue
-
29,37 g/m
-
PVC
-
85 ± 5 Shore A
-
lead-free, cadmium-free, CFC-free, silicone-free
-
4,5 mm
-
± 5 %
-
PVC
-
3
-
1,25 mm
-
± 5 %
-
45 ± 5 Shore D
-
good machinability
-
lead-free, cadmium-free, CFC-free, silicone-free
-
14
-
0,15 mm
-
0,25 mm²
-
Stranded copper wire, bare
-
Strand class 5
-
300 V
-
to DIN VDE 0298-4
-
4,5 A
-
79 Ω/km @ 20 °C
-
2 kV @ 60 s
-
2 kV @ 60 s
-
-30 °C
-
80 °C
-
-5 °C
-
80 °C
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
-
Good, application-related testing
-
Good, application-related testing
-
DIN EN 60811-404 | Good, application-related testing
-
5 x Outer diameter
-
10 x Outer diameter
-
-
X1
-
X2
-
X3
-
X4
-
Screw terminals SK
-
terminal
-
female
-
green
-
4
-
42
-
44
-
A 2
-
A 1
-
Screw terminals SK
-
terminal
-
female
-
green
-
4
-
21
-
24
-
22
-
41
-
Screw terminals SK
-
terminal
-
female
-
green
-
3
-
34
-
32
-
31
-
Screw terminals SK
-
terminal
-
female
-
green
-
3
-
12
-
11
-
14
27279218
27371001
-
27371601
27279218
27371601
27279218
27371601
27060311
27371601
27060313
27371601
27060313
27371601
27060313
27371601
EC001855
EC001437
4048879154680
4048879027649
1
1
85444290