Specification:M6FX8002-2DC34_1AF5

Art.No.: 7000-SS081-8800550
Weight: 0.439 kg
Country of origin:  DE

Description


Male straight – female straight
M12 – M12, 8-pole
Further cable lengths on request.
Plastic housings with good resistance against chemicals and oils.
The resistance to aggressive media should be individually tested for your application. Further details on request.

Cable length 5,5 m
Side 1
Tightening torque 0,6 Nm
Family construction form M12
Thread M12 x 1
Coding A
Width across flats SW13
Electrical data | Supply
Operating voltage AC max. 30 V
Operating voltage DC max. 30 V
Current operating per contact max. 2 A
Installation | Connection
Tightening torque 0,6 Nm
Device protection | Electrical
Degree of protection (EN IEC 60529) IP67
Mechanical data | Material data
Coating housing nickel plated
Material housing Brass
Mechanical data | Mounting data
Mounting method inserted, screwed, Shaking protection
Environmental characteristics | Climatic
Operating temperature min. -25 °C
Operating temperature max. 85 °C
Additional condition temperature range depending on cable quality

General data | Cable
Cable identification 880
Jacket Color green
Structure | Cable
Amount stranding 2
Stranding 2 wires twisted
Stranding (type 2) 2 wires around Stranding combination twisted
Cable shielding (type) copper braiding, bare
Cable shielding (coverage) 85 %
wire arrangement green, yellow, pink, blue, red, black
Mechanical data | Cable
No. of bending cycles (C-track) 5 Mio.
Cable weigth 75,9 g/m
Material jacket PUR
Outer-diameter (jacket) 6,9 mm
Tolerance outer diameter (sheath) ± 5 %
Material wire insulation Polyolefin
Amount wires 4
Conductor crosssection (wire) 0,2 mm²
Material wire insulation (Data) Polyolefin
Amount wires (Data) 2
Conductor crosssection wire (Data) 0,38 mm²
Temperature range | Cable
Min. operating temperature (static) -20 °C
Max. operating temperature (fixed) 80 °C
Operating temperature min. (dynamic) -20 °C
Operating temperature max. (dynamic) 60 °C
Resistances | Cable
Flame resistance UL 1581 § 1090 | UL 1581 § 1100 FT2 | IEC 60332-2-2
chemical resistance Good, application-related testing
Gasoline resistance Good, application-related testing
Oil resistance Good, application-related testing | DIN EN 60811-404
Installation | Cable
Bending radius (installation) x Outer diameter
Bending radius (fixed) x Outer diameter
Bending radius (dynamic) 10 x Outer diameter
Torsion stress ± 30 °/m

ECLASS-6.0 27061801
ECLASS-6.1 27060307
ECLASS-7.0 27060307
ECLASS-8.0 27060307
ECLASS-9.0 27060307
ECLASS-10.1 27060307
ECLASS-11.1 27060307
ECLASS-12.0 27060307
ETIM-5.0 EC000830
customs tariff number 85444290
GTIN 4048879687218
Packaging unit 1

 
Data Regarding Article:
  • Product-PDF
  • Construction files: STP 7000-48041_stp_x_a.zip (A)
  • Information: Certificate of conformity Murrelektronik GmbH 17-12-23_(1) RoHS REACh exception 6c_DoC_z_a.pdf (04)
  • Information: Certificate of conformity Murrelektronik GmbH 22-12-23_(6) California Prop65 Ni surface_DoC_z_a.pdf (01)