Ürünlerimizle alakalı sorularınız mı var? Uzmanlarımız size yardımcı olmaktan memnun olacaktır! Bizi arayın +90 212 222 2298

Ürün Karşılaştırma

 İleri̇
ürün kıyasla
Teknik Veriler
Side 1
Family construction form:
Material contact:
No. of poles:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Current operating per contact max.:
Installation
Connection cross section max.:
Installation | Connection
Connection:
Tightening torque:
Width across flats:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Insulation resistance min.:
Overvoltage category (EN 60950-1):
Mechanical data | Material data
Coating contact:
Material housing:
Locking material:
Mechanical data | Mounting data
Mounting method:
Clamping range min.:
Clamping range max.:
Height:
Width:
Depth:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Important installation notes
Note on strain relief:
Note on bending radius:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Ticari bilgiler
GTIN:
Paket miktarı:
Gümrük tarife no (gtip):
Onaylar
Certificates
Certificate
Certificate
Certificate
Ürün taşı
M12 male 0° A-cod. screw terminal M12 male 0° A-cod. screw terminal
4-pol., max. 0,75mm², 4 - 6mm
Ağırlık 0.023 kg
Ürün No. 7000-12702-0000000

Ürün taşı
M12 male 0° A-cod. screw terminal M12 male 0° A-cod. screw terminal
4-pol., max. 0,75mm², 4 - 6mm
Ağırlık 0.023 kg
Ürün No. 7000-12701-0000000

M12
M12
Copper alloy
-
4
-
IP67
IP67
250 V
250 V
250 V
250 V
4 A
4 A
0,75 mm²
0,75 mm²
Screw terminals SK
-
0,6 Nm
0,6 Nm
SW18
-
inserted, screwed
inserted, screwed
3
3
-
2,5 kV
100 MΩ
-
II
-
gold plated
-
PBT
-
Copper alloy
-
-
inserted, screwed, Shaking protection
4 mm
4 mm
6 mm
6 mm
-
60 mm
-
20 mm
-
20 mm
-40 °C
-40 °C
85 °C
85 °C
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
27279221
27279221
27260702
-
27440102
27440104
27440102
27440104
27440116
27440102
27440102
27440102
27440102
27440102
27440116
27440116
EC001855
EC002635
4065909040850
4048879201667
1
1
85366990
85366990
-
-