Tem questões sobre os nossos produtos? Os nossos especialistas terão todo o prazer em ajudá-lo! Contacte-nos (11) 5632-3000

Comparar

 Avançar
Artigo
Dados tecnicos
Cable length:
Side 1
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material contact:
No. of poles:
Width across flats:
Side 2
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material contact:
No. of poles:
Width across flats:
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data | Material data
Coating locking:
Material gasket:
Material housing:
Locking material:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Dados de cabo
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Dados comerciais
Classificação fiscal:
GTIN:
Quantidade por embalagem:
Aprovações
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Mover o produto
M8 male 0° / M12 female 0° A-cod. M8 male 0° / M12 female 0° A-cod.
PVC 3x0.25 ye UL/CSA 1.5m
Peso: 0.056 kg
Número de Artigo: 7000-88241-0100150

Mover o produto
M8 male 0° / M12 female 0° A-cod. M8 male 0° / M12 female 0° A-cod.
PVC 3x0.25 gy UL/CSA 1.5m
Peso: 0.06 kg
Número de Artigo: 7000-88241-2100150

1,5 m
1,5 m
0,4 Nm
0,4 Nm
inserted, screwed
inserted, screwed
gold plated
gold plated
M8
M8
M8 x 1
M8 x 1
6,5 mm
6,5 mm
A
A
Copper alloy
Copper alloy
3
3
SW9
SW9
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
gold plated
gold plated
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
A
A
Copper alloy
Copper alloy
3
3
SW13
SW13
50 V
50 V
60 V
60 V
30 V
30 V
30 V
30 V
4 A
4 A
IP65, IP67, IP68, IP66K
IP65, IP67, IP68, IP66K
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
Nickeled
Nickeled
FKM
FKM
PUR
PUR
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12), DIN EN 61076-2-114 (M8)
DIN EN 61076-2-101 (M12), DIN EN 61076-2-114 (M8)
010
210
1
1
yellow
gray
cURus
cURus
1
1
3 wires twisted
3 wires twisted
brown, black, blue
brown, black, blue
29,37 g/m
29,37 g/m
PVC
PVC
85 ± 5 Shore A
85 ± 5 Shore A
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
4,5 mm
4,5 mm
± 5 %
± 5 %
PVC
PVC
3
3
1,25 mm
1,25 mm
± 5 %
± 5 %
45 ± 5 Shore D
45 ± 5 Shore D
good machinability
good machinability
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
14
14
0,15 mm
0,15 mm
0,25 mm²
0,25 mm²
Stranded copper wire, bare
Stranded copper wire, bare
Strand class 5
Strand class 5
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
79 Ω/km @ 20 °C
79 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-30 °C
-30 °C
80 °C
80 °C
-5 °C
-5 °C
80 °C
80 °C
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
85444290
85444290
4048879414678
4048879124447
1
1