Artigo
Dados tecnicos
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Stripping length (jacket):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Installation | Connection
Stripping length (jacket):
Mounting set:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data | Material data
Coating locking:
Coating of fitting:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Dados de cabo
General data | Cable
STOOW style jacket:
Cable identification:
Cable Type:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Stranding factor max. (type 5):
Amount stranding:
Stranding:
Stranding factor min.:
Stranding factor max.:
Amount stranding (type 2):
Stranding (type 2):
Stranding factor min. (type 2):
Stranding factor max. (type 2):
Amount stranding (type 3):
Stranding (type 3):
Stranding factor min. (type 3):
Stranding factor max. (type 3):
Cable shielding (type):
Cable shielding (coverage):
Pair shielding (type):
Banding:
Filler:
Drain wire (type):
Drain wire (cross-section):
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Cable length max.:
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Travel speed (C-track):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Resistances wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Drain wire (cross-section):
Material conductor wire:
Conductor type (wire):
Electrical function wire:
Material wire insulation (Data):
Outer diameter wire insulation (Data):
Tolerance outer diameter wire insulation (data):
Shore hardness wire insulation (Data) :
Material properties wire insulation (Data):
Ingredient freeness wire insulation (Data):
Resistances wire insulation (Data):
Printing color wire insulation (data):
Printing spacing wire insulation (Data):
Amount wires (Data):
Amount strands wire (Data):
Diameter of single wires (Data):
Conductor crosssection wire (Data):
Material conductor wire (Data):
Wire conductor type (Data):
Electrical function wire (data):
Material wire insulation (Power):
Outer diameter wire insulation (Power):
Tolerance outer diameter wire insulation (Power):
Shore hardness wire insulation (Power):
Material properties wire insulation (Power):
Ingredient freeness wire insulation (Power):
Resistances wire insulation (Power):
Printing colour wire insulation (Power):
Printing spacing wire insulation (Power):
Amount strands wire (Power):
Diameter of single wires (Power):
Wire conductor cross section (Power):
Material conductor wire (Power):
Conductor type wire (Power):
Electrical function wire (Power):
Electrical data | Cable
Loop resistance:
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Electrical function wire:
Electrical function wire (data):
Characteristic impedance:
Electrical resistance line constant wire:
Electrical resistance coating wire (Power):
Electrical resistance coating wire (Data):
AC withstand voltage (wire - wire):
Electric inductivity line constant:
Electric capacitance:
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Transmission frequency range:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Storage temperature min.:
Storage temperature max.:
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (installation):
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Dados comerciais
Classificação fiscal:
GTIN:
Quantidade por embalagem:
Aprovações
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Mover o produto
M12 male 0° A-cod. with cable M12 male 0° A-cod. with cable
PUR 5x0.34 ye UL/CSA 2m
Peso: 0.115 kg
Número de Artigo: 7000-12041-0250200

Mover o produto
M12 male 0° A-cod. with cable M12 male 0° A-cod. with cable
PUR 5x0.34 ye UL/CSA+drag ch. 2m
Peso: 0.096 kg
Número de Artigo: 7000-12041-0350200

2 m
2 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
A
A
PUR
PUR
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
20 mm
20 mm
125 V
125 V
125 V
125 V
30 V
30 V
30 V
30 V
4 A
4 A
20 mm
20 mm
M12 x 1
M12 x 1
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
Nickeled
Nickeled
nickel plated
nickel plated
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
-
-
834
035
-
3
-
-
-
-
blue
yellow
cURus
cURus
-
-
1
1
2 wires twisted
5 wires around Core filler twisted
-
-
-
-
1
-
2 Stranded joints twisted
-
-
-
-
-
-
-
-
-
-
-
-
-
copper braid, tinned
-
65 %
-
-
-
Foil
-
-
yes
-
-
22 AWG
-
(white, blue), (black, red)
brown, black, blue, white, green-yellow
5 m
10 m @ 25 °C | horizontal
-
-
63,12 g/m
41,8 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
-
6,9 mm
4,8 mm
± 5 %
± 5 %
-
-
-
-
PE
PP
2
5
2,1 mm
1,25 mm
± 5 %
± 5 %
64 ± 5 Shore D
70 ± 5 Shore D
-
-
lead-free, CFC-free, halogen-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
-
-
-
-
-
19
42
24 AWG
0,1 mm
24 AWG
0,34 mm²
22 AWG
-
copper stranded wire, tinned
Stranded copper wire, bare
-
strand class 6
Data
-
PE
-
1,5 mm
-
± 53 %
-
-
-
-
-
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
-
2
-
19
-
22 AWG
-
22 AWG
-
copper stranded wire, tinned
-
-
-
Power
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
300 V
300 V
-
-
-
-
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
6 A
-
Data
-
Power
-
120 Ω ± 10 % @ 1 MHz
-
78 Ω/km
57 Ω/km @ 20 °C
-
-
54 Ω/km
-
2 kV @ 60 s
2,5 kV @ 60 s
-
-
40000 pF/km
-
-
-
-
-
-
2,5 kV @ 60 s
2 kV @ 60 s
-
-
-
-40 °C
-40 °C
80 °C
80 °C / 90 °C @ 10000 h Operation
-30 °C
-25 °C
70 °C
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
x Outer diameter
-
6 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
1 Mio.
10 Mio. @ 25 °C
2 Mio.
2 Mio.
± 30 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
-
27279218
27279218
27279218
27279218
27060311
27060311
27060311
-
27060311
-
27060311
-
EC001855
EC001855
85444290
85444290
4048879512176
4065909056318
1
1