저희 제품과 관련하여 질문이 있으시면 문의 주십시오. 본사의 전문가가 성심껏 도와드리겠습니다! 1833-8183

제품 비교

 전달하기
제품
기술자료
Cable length:
Electrical data | Supply
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Current consumption max.:
Diagnostics
Status indication LED:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Device protection | Media
Flame resistance:
Mechanical data | Material data
Color housing:
Material housing:
Locking material:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
케이블 데이터
Cable
wire arrangement:
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
제품자료
GTIN:
포장단위:
세번부호:
더보기
Valve plug MJC 0° with cable LED V2A Valve plug MJC 0° with cable LED V2A
PUR 2x0.5 bk drag ch. 3m
무게 0.115 kg
Art.No.: 7072-70021-7400300

더보기
Valve plug MJC 90° with cable LED V2A Valve plug MJC 90° with cable LED V2A
PUR 2x0.5 bk drag ch. 3m
무게 0.115 kg
Art.No.: 7072-70321-7400300

3 m
3 m
12 V
12 V
24 V
24 V
12 V
12 V
24 V
24 V
4 A
4 A
12 mA
12 mA
yellow
yellow
IP65
IP65
inserted, locked
inserted, locked
flame retardant
flame retardant
black
black
Plastic
Plastic
Stainless steel 1.4305 (V2A)
Stainless steel 1.4305 (V2A)
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
black, white
black, white
740
740
black
black
-
-
1
1
2 wires twisted
2 wires twisted
black, white
black, white
36,3 g/m
36,3 g/m
PUR
PUR
85 Shore A
85 Shore A
lead-free, cadmium-free, CFC-free, halogen-free
lead-free, cadmium-free, CFC-free, halogen-free
5 mm
5 mm
± 5 %
± 5 %
TPE-E
TPE-E
2
2
1,5 mm
1,5 mm
± 5 %
± 5 %
70 Shore A
70 Shore A
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
64
64
0,1 mm
0,1 mm
0,5 mm²
0,5 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
500 V
500 V
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
9 A
9 A
39 Ω/km @ 20 °C
39 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-50 °C
-50 °C
90 °C
90 °C
-30 °C
-30 °C
90 °C
90 °C
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
10 x Outer diameter
10 x Outer diameter
2 Mio. @ 25 °C
2 Mio. @ 25 °C
5 m @ 25 °C | horizontal
5 m @ 25 °C | horizontal
3,3 m/s @ 25 °C
3,3 m/s @ 25 °C
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879316460
4048879312479
1
1
85444290
85444290